{"title":"Nitrous Oxide Controllers","description":null,"products":[{"product_id":"2-stage-mini-progressive-nitrous-controller-25974nos","title":"NOS\/Nitrous Oxide System Mini 2-Stage Progressive Nitrous Controller with Touch Screen Programmer 25974NOS","description":"The LCD also displays RPM, bottle pressure (optional), and stage activation providing robust monitoring of your Nitrous system.\u003cp\u003e\u003cbr\u003eNOS\/Nitrous Oxide System Mini 2-Stage Progressive Nitrous Controller with Touch Screen Programmer 25974NOS\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eSpecifications:\u003cbr\u003e\u003c\/p\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eNOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eNitrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission Code\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal Percentage\u003c\/td\u003e\n\u003ctd\u003e0 - 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgressive Time\u003c\/td\u003e\n\u003ctd\u003e0 - 9.9 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eTouch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003ctd\u003eCalifornia Proposition 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eManufacturer's Limited 90 Day Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eNOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eNitrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission Code\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal Percentage\u003c\/td\u003e\n\u003ctd\u003e0 - 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgressive Time\u003c\/td\u003e\n\u003ctd\u003e0 - 9.9 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eTouch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003ctd\u003eCalifornia Proposition 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eManufacturer's Limited 90 Day Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_INV\u003c\/td\u003e\n\u003ctd\u003eNOS PROGRESSIVE N2O CONTROLLER V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_DES\u003c\/td\u003e\n\u003ctd\u003eNOS Mini 2-Stage Progressive Nitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_EXT\u003c\/td\u003e\n\u003ctd\u003eMini 2-Stage Progressive Nitrous Controller with Touch Screen Programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eGetting the most out of your nitrous system and putting more power to the ground when traction is at its best is the goal with anyone using nitrous as a Power Adder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eThe new, updated Mini 2-stage progressive nitrous controller from NOS is packed with features that makes that challenge much easier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eTwo completely independent stages of nitrous\/fuel control, each with independent throttle position activation switch and progressive ramps.  RPM on\/off control eliminates the need for a window switch and allows you to turn the nitrous on and off at set points \u0026amp; conditions. Two programmable outputs, allowing control of timing retard or other devices. The hand held 2.4\" LCD touch screen display (w\/ included stylus), makes programming quick and simple and allows you to mount the main controller housing out of sight.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eThe LCD also displays RPM, bottle pressure (optional), and stage activation providing robust monitoring of your Nitrous system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eNew Mini 2-Stage Progressive Nitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eNew Hand Held Color LCD 2.4” Touch Screen Display w\/ Micro SD Memory Card to Store Tunes and Software Updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eTouch screen Stylus included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003e2 Fully Independent Stage Outputs – Allows Programming in Any Curve Shape or With Built-in Ramp Builder Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eProgressive Solenoid Operation Based on Time, RPM, and\/or TPS (Throttle Position Sensor) Input and Can Shut Nitrous Off at a Programmed RPM Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eController Housing Designed and Constructed to Handle Harsh Conditions in a Racing Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eAllows the User to Drive the Solenoids at Different Duty Cycles to Tailor Power Delivery to the Engine as Needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eOptional Bottle Pressure Transducer Input Allows Precise Bottle Pressure Monitoring Without Leaving the Driver’s Seat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_INV\u003c\/td\u003e\n\u003ctd\u003eNOS PROGRESSIVE N2O CONTROLLER V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_DES\u003c\/td\u003e\n\u003ctd\u003eNOS Mini 2-Stage Progressive Nitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_EXT\u003c\/td\u003e\n\u003ctd\u003eMini 2-Stage Progressive Nitrous Controller with Touch Screen Programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eGetting the most out of your nitrous system and putting more power to the ground when traction is at its best is the goal with anyone using nitrous as a Power Adder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eThe new, updated Mini 2-stage progressive nitrous controller from NOS is packed with features that makes that challenge much easier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eTwo completely independent stages of nitrous\/fuel control, each with independent throttle position activation switch and progressive ramps.  RPM on\/off control eliminates the need for a window switch and allows you to turn the nitrous on and off at set points \u0026amp; conditions. Two programmable outputs, allowing control of timing retard or other devices. The hand held 2.4\" LCD touch screen display (w\/ included stylus), makes programming quick and simple and allows you to mount the main controller housing out of sight.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eThe LCD also displays RPM, bottle pressure (optional), and stage activation providing robust monitoring of your Nitrous system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eNew Mini 2-Stage Progressive Nitrous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eNew Hand Held Color LCD 2.4” Touch Screen Display w\/ Micro SD Memory Card to Store Tunes and Software Updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eTouch screen Stylus included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003e2 Fully Independent Stage Outputs – Allows Programming in Any Curve Shape or With Built-in Ramp Builder Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eProgressive Solenoid Operation Based on Time, RPM, and\/or TPS (Throttle Position Sensor) Input and Can Shut Nitrous Off at a Programmed RPM Ceiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eController Housing Designed and Constructed to Handle Harsh Conditions in a Racing Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eAllows the User to Drive the Solenoids at Different Duty Cycles to Tailor Power Delivery to the Engine as Needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eOptional Bottle Pressure Transducer Input Allows Precise Bottle Pressure Monitoring Without Leaving the Driver’s Seat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NOS\/Nitrous Oxide System","offers":[{"title":"Default Title","offer_id":42427256209456,"sku":"BHHV_25974NOS","price":299.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/9548\/3440\/files\/NOS25974NOS.jpg?v=1758738589"},{"product_id":"time-delay-relay-15838anos","title":"NOS\/Nitrous Oxide System NOS Digi-Set Time Delay Relay Switch (DIP Switch) 15838ANOS","description":"NOS Digi-Set Time Delay Relay Switch (DIP Switch) - Allows you to activate a second or third stage of nitrous (or other electronic device) as a function of time.  Delay is easily set from 1\/10th of a second to almost two minutes, in 1\/10th second increments, by setting the small switches on the top of the timer.  Available with DIP switch settings.\u003cp\u003e\u003cbr\u003eNOS\/Nitrous Oxide System NOS Digi-Set Time Delay Relay Switch (DIP Switch) 15838ANOS\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eSpecifications:\u003cbr\u003e\u003c\/p\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eNOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eAir and Fuel Delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission Code\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart type\u003c\/td\u003e\n\u003ctd\u003eNitrous Oxide Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTime Delay Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003e10 DIP Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub Category\u003c\/td\u003e\n\u003ctd\u003eControl Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime\u003c\/td\u003e\n\u003ctd\u003e0.1 - 102.3 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger\u003c\/td\u003e\n\u003ctd\u003e12v\/ Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003ctd\u003eCalifornia Proposition 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eManufacturer's Limited 90 Day Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eNOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eAir and Fuel Delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission Code\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart type\u003c\/td\u003e\n\u003ctd\u003eNitrous Oxide Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTime Delay Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003e10 DIP Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub Category\u003c\/td\u003e\n\u003ctd\u003eControl Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime\u003c\/td\u003e\n\u003ctd\u003e0.1 - 102.3 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger\u003c\/td\u003e\n\u003ctd\u003e12v\/ Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003ctd\u003eCalifornia Proposition 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eManufacturer's Limited 90 Day Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_INV\u003c\/td\u003e\n\u003ctd\u003eRELAY, TIME DELAY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_DES\u003c\/td\u003e\n\u003ctd\u003eNOS Time Delay Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_EXT\u003c\/td\u003e\n\u003ctd\u003eNOS Digi-Set Time Delay Relay Switch (DIP Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eNOS Digi-Set Time Delay Relay Switch (DIP Switch) - Allows you to activate a second or third stage of nitrous (or other electronic device) as a function of time.  Delay is easily set from 1\/10th of a second to almost two minutes, in 1\/10th second increments, by setting the small switches on the top of the timer.  Available with DIP switch settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eDelay Easily Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eIn 1\/10th Second Increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eAvailable with DIP Settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_INV\u003c\/td\u003e\n\u003ctd\u003eRELAY, TIME DELAY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_DES\u003c\/td\u003e\n\u003ctd\u003eNOS Time Delay Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_EXT\u003c\/td\u003e\n\u003ctd\u003eNOS Digi-Set Time Delay Relay Switch (DIP Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_MKT\u003c\/td\u003e\n\u003ctd\u003eNOS Digi-Set Time Delay Relay Switch (DIP Switch) - Allows you to activate a second or third stage of nitrous (or other electronic device) as a function of time.  Delay is easily set from 1\/10th of a second to almost two minutes, in 1\/10th second increments, by setting the small switches on the top of the timer.  Available with DIP switch settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eDelay Easily Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eIn 1\/10th Second Increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription_FAB\u003c\/td\u003e\n\u003ctd\u003eAvailable with DIP Settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NOS\/Nitrous Oxide System","offers":[{"title":"Default Title","offer_id":42427269808176,"sku":"BHHV_15838ANOS","price":332.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/9548\/3440\/files\/NOS15838A.jpg?v=1758738974"}],"url":"https:\/\/berryperformancesales.com\/collections\/nitrous-oxide-controllers.oembed","provider":"Berry Performance Sales","version":"1.0","type":"link"}